- You are here :
- Home
- Flow
- Calorimetry
- Taxonomy page
Flow sensor working according to the calorimetric principle
The powerful industrial professional for demanding applications involving air and gases
- Can be used for flow measurement of air and various gases
- Precise measurement results even at high overpressures and over wide temperature ranges
- Sensor length up to 1m
- Output signals for flow and temperature
- EX version available
Flow sensor working according to the calorimetric principle, for gases
The inexpensive alternative for overpressure up to 10 bar
- Direct measurement of the standard flow velocity up to 90 m/s without additional pressure or temperature compensation or calculations
- High precision calibration including ISO calibration protocol (optional)
- Overpressure up to 10 bar
Flowmeter / flow sensor for gases, working according to the calorimetric principle (anemometer)
The smallest all-rounder - for universal use and high-performance
- Energy-efficient control of ventilators
- Continuous monitoring of filter units
- Safe control of the volume flow during suction
- Monitoring of laminar flow in clean rooms
Anemometer for high-precision laminar flow monitoring of clean rooms (industry and pharmaceuticals)
- Precise measurement of low air speeds
- Sensor version: Thermopile
- With direction detection
- With switching outputs
- Response time: from 0.01 s
- Disinfectable with alcohols and H2O2 (VHP suitable)
- Self-monitoring and output of error signals
- Special lengths up to 1,000 mm (straight version)
Anemometer for high-precision laminar flow monitoring of clean rooms (industry and pharmaceuticals)
Precise measurement of low air speeds
Sensor version: dumbbell head
Additional temperature measurement
Also suitable for aggressive media
Disinfectable with alcohols and H2O2 (VHP suitable)
Self-monitoring and output of error signals
Special lengths up to 1,000 mm (straight version)
Flow and temperature sensor working according to the calorimetric principle, for air and gases
- Maintenance-free, robust and long-term stable
- Highest reproducibility of the measurement results
- Evaluation electronics in the sensor tube
- Flow independent assembly
- Variable, infinite immersion depth, extendablel
Flow sensor working according to the calorimetric principle, for air and gases
- Shortest inlet and outlet paths thanks to multi-point measurement
- Direct measurement of standard volume flow and temperature
- Low pressure drop
- Modularly expandable
- Easy installation, integrated measuring section
- Highest measuring accuracy, even in connection with flow obstacles