Pressure switches

09.06.2015
Pressure switches

The functional safety of pressure monitoring is becoming increasingly important in industrial process engineering. We have therefore expanded our portfolio with the pressure switches from the manufacturer Fema Honeywell. As a Fema wholesaler, we provide you with SIL-compliant devices for your safety-relevant areas of application.

For potentially explosive atmospheres, Fema provides a range of pressure switches with the type of protection "flameproof enclosure Ex-d" according to directive 94/9 / ATEX. For the Ex-i area, various pressure switch series with gold contact and Ex-i equipment are available under the generic term "simple electrical equipment", which are also part of the current type examination. Type examination certificates according to ATEX and IEC Ex are available.

Table 1 lists the most common pressure switches for use in industrial processes. If you cannot find a suitable pressure switch for your system in this table, please contact us. There are other special designs available.

Pressure ranges Medium* Design Guidelines for CE Standards Type
0.2 mbar - 150 mbar Air, fuel gases Differential pressure switch EU/2009/142/EG DIN EN1854 HCD**
20 Pa - 2500 Pa Air and non aggressive gases Differential pressure switch EU/2009/142/EG DIN EN1854 DPS**
1 bar - 63 bar Non aggressive liquids and gases Mechanical pressure switch RL 2006/95/EG DIN EN60730 DCM
DNM
1 bar - 63 bar Non aggressive liquids and gases Mechanical pressure switch for Ex areas ATEX 94/9/EG DIN EN60730
DIN EN60079
Ex-DCM
Ex-DNM
-1 bar - 16 bar Aggressive liquids and gases Pressure / vacuum switch with stainless steel sensor made of 1.4571 RL 2006/95/EG DIN EN60730 DNS
VNS
-1 bar - 16 bar Aggressive liquids and gases Ex pressure / Ex vacuum switch with stainless steel sensor made of 1.4571 ATEX 94/9/EG DIN EN60730
DIN EN60079...
Ex-DNS
Ex-VNS
4 mbar - 16 bar Liquids and gases Differential pressure switch ATEX 94/9/EG DIN EN60730 DDCM
4 mbar - 16 bar Liquids and gases Differential pressure switch for Ex areas RL 2006/95/EG DIN EN60730 DIN EN60079 Ex-DDCM
-1 bar - 0.5 bar Liquids and gases Vacuum switch RL 2006/95/EG DIN EN60730 VCM
VNM
-1 bar - 0.5 bar Liquids and gases Ex vacuum switch ATEX 94/9/EG DIN EN60730
DIN EN60079
Ex-VCM
Ex-VNM
0.1 bar - 32 bar Steam, hot water Pressure monitor, pressure limiter DGR 97/23/EG VdTÜV Druck100 DIN EN12952-11
DIN EN12953-9
DWAM
DWAMV
SDBAM
0.1 bar - 40 bar Liquids and gases Line monitoring with isolating switching amplifier (on site)

DGR 97/23/EG
ATEX 94/9/EG

VdTÜV Druck100 DIN EN 1854
EN 13611
DIN EN12952-11 DIN EN12953-9
DWAM...-576
DWR...-576
3 bar - 16 bar Liquefied gas Line monitoring with isolating switching amplifier (on site) DGR 97/23/EG
ATEX 94/9/EG
VdTÜV Druck100 DIN EN 764-7 FD
15 mbar - 1.6 bar Fuel gas Pressure switch EU/2009/142/EG DIN EN1854
DIN EN13611
DGM
15 mbar - 250 mbar Fuel gas Pressure switch for Ex area ATEX 94/9/EG
EU/2009/142/EG
DIN EN1854
DIN EN13611
DIN EN60079
Ex-DGM
0.1 bar - 40 bar Steam, hot water, fuel gases, liquefied fuels Pressure switch "special design" by testing with 2 million switching cycles DGR 97/23/EG VdTÜV Druck100
DIN EN 1854
DIN EN12952-11
DIN EN12953-9
DWR
0.1 bar - 40 bar Steam, hot water, fuel gases, liquefied fuels Ex Pressure switch "special design" by testing with 2 million switching cycles DGR 97/23/EG
ATEX 94/9/EG
 
VdTÜV Druck100 DIN EN 1854
DIN EN12952-11
DIN EN12953-9
DIN EN60079
Ex-DWR

 

Table 1: Fema - pressure switches
* Wetted materials are listed in the respective data sheets. The test for media resistance is generally the responsibility of the planner or the technical decision-maker.
** Pressure switches without SIL certification