Oval wheel conter for liquids
- Independent of viscosity
- No inlet and outlet paths required
- High measuring accuracy and reproducibility
- Insensitive to vibrations and pressure changes
- Easy installation
- Flange connection
Delivery time:
approx. 3 weeks
<<<<<<<<<<Delivery time
approx. 3 weeks
Measuring range | 1 L/min up to 700 L/min |
Error* | 0.1% from the measured value |
Medium temperature | -10°C - +70°C |
Ambient temperature | -20°C - +70°C |
Process connection | Flange DIN DN15/25/50; ANSI ½“, 1“, 2“ |
*at reference conditions >3 mPa·s
More information:
- Oval wheel meters for small flows
- New: oval wheel meter - independent of viscosity, precise, durable
Accessories:
Documents (English) | Size |
---|---|
Data sheet oval wheel meter Flowal OF MFE | 216.19 KB |
Operating manual oval wheel meter Flowal OR and Flowal OF | 1.17 MB |
Documents (German) | Size |
---|---|
Datenblatt Ovalradzähler Flowal OF.MFE | 178.38 KB |
Bedienungsanleitung Ovalradzähler Flowal OR und Flowal OF | 978.8 KB |