Configure your turbine and impeller flow meter for water and slightly viscous liquids to suit your application.
If you cannot find a suitable device in our list of standard devices, please inform us about your needs. Schmidt Mess- und Regeltechnik will make you an individual offer.
Type | Measuring | Flow | Measuring | Repeatability | Operating | Compressive | Material | Material | Viscosity | Electrical | Special features |
G2 | turbine | 3.7 - 760 l/min | ±0.75 - ±2.0%of reading | ±0.1 - ±0.3% | -40 - +121°C | 6.9 - 207 bar | 316 stainless steel | PVDF | <100 cSt |
| |
TM | turbine | 3.8 - 2271 l/min | ±3.0% | 0 - +60°C | 9.1 bar | PVC | PVDF | pulse output |
| ||
DW-FS | impeller | 2.5 - 580 l/min | ±2% | -40 - +100°C | 20 bar | stainless steel (1.4571) | POM | 4 - 20 mA calibratable |
| ||
HAL | impeller | 2.5 - 580 l/min | ±2% | -40 - +100°C | 25 bar | stainless steel | POM | 4 - 20 mA |
| ||
HAL-A | impeller | 0.3 - 5 m/s | ±2% | -40 - +100°C | 25 bar | stainless steel | POM | 4 - 20 mA |
| ||
FHKU | impeller | 0.041 - 15 l/min | ±2% | ±0.25% | 0 - +60°C | 10 bar | PBT 35%GF (Arnite) | PVDF |
| ||
Vision | turbine | 0.5 - 35 l/min | ±3% | ±0,5% | -20 - +100°C | 25 bar | Grilamid TR55 (PA12) | Grilamid (PA12 Ferrit) | up to approx. 15 cSt | pulses through open collector NPN |
|
DF 04 | impeller | 2 - 1000 l/min | ±1% | <0,5 % | 0 - +85°C | 10 bar | PP | PP | 0.5 - 20 cSt |
|
Documents (English) | Size |
---|---|
Turbine and impeller flow meters | 120.02 KB |
Documents (German) | Size |
---|---|
Turbinen- und Flügelrad-Durchflussmesser | 121.05 KB |